Product Introduction
Cryogenic Extended Bonnet Forged Steel Ball Valves provide quarter-turn isolation for pipelines handling liquefied gases and other low-temperature media. The forged steel body contains line pressure, while the extended bonnet positions the stem packing away from the cold valve body. Material grades, pressure rating, seat design, and bonnet dimensions are selected according to the operating temperature, process medium, and pipeline requirements.
Key Advantages
Extended Bonnet Design
The extended bonnet provides separation between the cryogenic fluid and the stem packing area. Its dimensions are determined by the valve design and specified operating conditions.
Forged Steel Body
The forged body provides the pressure-containing structure. Material grade and heat treatment are specified according to design pressure, minimum service temperature, and applicable material requirements.
Quarter-Turn Operation
A 90-degree rotation moves the ball between open and closed positions. Manual, gear, pneumatic, or electric operation can be specified according to valve size and operating torque.
Cryogenic Sealing Configuration
Seat and packing materials are selected according to operating temperature, pressure differential, fluid compatibility, and required shut-off performance.
Technical Specifications
|
Parameter |
Specification |
|
Valve Type |
Cryogenic Ball Valve |
|
Body Construction |
Forged Steel |
|
Nominal Size |
DN15–DN600 |
|
Inch Size |
1/2–24 in |
|
Pressure Class |
ASME Class 150–1500 |
|
Reference Minimum Temperature |
-196°C |
|
Operating Angle |
90° |
|
Operation |
Manual, Gear, Pneumatic, Electric |
|
End Connections |
Flanged, Butt Weld |
|
Ball Configuration |
Floating or Trunnion Mounted |
|
Seat Configuration |
Soft Seated or Metal Seated |
|
Design Standard |
ASME B16.34, where applicable |
|
Testing Standard |
Applicable valve testing standard |
Materials and Construction
Body and Bonnet
Forged steel grades are selected according to design pressure, minimum design temperature, and process fluid requirements. Material specifications are confirmed against the applicable design standard.
Ball and Stem
Stainless steel or other compatible alloys may be specified according to strength, corrosion resistance, and fluid compatibility requirements.
Seats and Packing
Seat materials are selected for the required temperature range, pressure differential, and shut-off conditions. Stem packing is specified for the intended cryogenic service.
Material Traceability
Material identification and certificates can be provided according to the agreed material specifications and documentation requirements.
Applications
LNG Systems
Isolation in liquefied natural gas processing, storage, loading, and transfer pipelines.
Industrial Gas Systems
Pipeline isolation for liquid nitrogen, liquid argon, and other compatible cryogenic media.
Low-Temperature Process Lines
Isolation in petrochemical and industrial process systems operating within the approved pressure and temperature limits.
Cryogenic Storage and Transfer
Valve applications in storage tanks, transfer lines, and associated process piping requiring cryogenic shut-off.
Customization Options
Size and Pressure Rating
Nominal size and pressure class can be specified according to pipeline design and the confirmed manufacturing range.
Material Selection
Body, bonnet, ball, stem, seat, and packing materials can be selected for the specified medium and temperature conditions.
Connection Design
Flanged or butt-weld connections can be specified according to the applicable piping standard and installation dimensions.
Operating Configuration
Manual, gear, pneumatic, or electric operation can be selected according to torque requirements, installation space, and control interfaces.
Technical Documentation
Dimensional drawings, product datasheets, material certificates, inspection records, and test reports can be supplied according to agreed project requirements.
Quality Inspection and Testing
Material Inspection
Material grades and identification are checked against approved specifications and applicable documentation requirements.
Dimensional Inspection
Critical dimensions, end connections, bonnet extension, and mounting interfaces are checked against approved drawings.
Pressure Testing
Shell and seat tests are performed according to the applicable testing standard and agreed acceptance criteria.
Cryogenic Testing
Cryogenic testing can be specified according to project requirements. Test temperature, procedure, acceptance criteria, and reporting requirements are established before production.
Inspection Records
Material certificates, inspection reports, and test documentation are prepared according to the agreed inspection plan.
Product Selection Guide
Operating Conditions
Specify the process medium, minimum and maximum operating temperatures, design pressure, and required shut-off conditions.
Pipeline Requirements
Confirm nominal size, pressure class, end connection, face-to-face dimensions, and applicable design standards.
Valve Configuration
Identify the required ball design, seat materials, operating method, flow direction, and installation constraints.
Inspection Requirements
Define pressure tests, cryogenic testing, material traceability, inspection witness points, and required documentation.
Drawing Approval
Review the final datasheet and dimensional drawing before order confirmation to verify compatibility with the intended installation.
Frequently Asked Questions
Q: Why does a cryogenic ball valve require an extended bonnet?
A: The extended bonnet increases the distance between the cold valve body and the stem packing area, helping maintain suitable packing conditions during low-temperature operation.
Q: What is the minimum operating temperature?
A: The reference temperature is -196°C. The approved minimum temperature depends on the selected materials, sealing components, valve design, and specified testing requirements.
Q: Which pressure classes are available?
A: Pressure class availability depends on valve size, material selection, design, and manufacturing range. The required rating must be confirmed for the specified operating conditions.
Q: Can the valve be customized?
A: Yes. Size, pressure class, materials, connections, operating method, and documentation can be specified according to the confirmed manufacturing capabilities.
Q: Is cryogenic testing available?
A: Cryogenic testing can be included when specified in the agreed technical requirements. The test temperature, procedure, acceptance criteria, and report format are confirmed during technical review.
Hot Tags: cryogenic extended bonnet forged steel ball valve, China cryogenic extended bonnet forged steel ball valve manufacturers, suppliers, factory, 1 piece ball valves, ball valve 12 inch, ball valve with gauge, high temperature ball valves, side entry ball valves, threaded ball valve